在使用光模块的时候,你是不是也常常遇到各种各样的故障问题?像光模块型号选用是否正确、使用的跳线是否正确?虽然解决方案咱有,但遇到传输异常等问题时,好多人都不知道要如何排查、解决。今天这篇就教你用命令排查光模块故障!以及,为了减少光模块在使用中故障发生的概率,还是得用性能可靠稳定且品质有保障的光模块啊。当然,正确专业的操作方式也少不了。
01光模块故障定位常用命令
根据光模块的告警信息查找故障原因:
display interface transceiver
查看光模块光功率是否正常:
display interface transceiver verbose
02根据光模块的告警信息查找故障原因
执行命令display interface transceiver查看“Alarm information”下光模块是否有告警信息。
<HUAWEI> display interface 10ge 1/0/1 transceiver
10GE1/0/1 transceiver information:
-------------------------------------------------------------------
Common information:
Transceiver Type :10GBASE_SR
Connector Type :LC
Wavelength (nm) :850
Transfer Distance (m) :30(62.5um/125um OM1)
80(50um/125um OM2)
300(50um/125um OM3)
400(50um/125um OM4)
Digital Diagnostic Monitoring :YES
Vendor Name :HUAWEI
Vendor Part Number :02318169
Ordering Name :
-------------------------------------------------------------------
Manufacture information:
Manu. Serial Number :AQG269Y
Manufacturing Date :2013-10-20
Vendor Name :HUAWEI
-------------------------------------------------------------------
Alarm information:
-------------------------------------------------------------------
如果出现LOS Alarm告警,则说明对端没有信号发送过来,在接口模式下执行命令display this查看两端端口是否shutdown,如果端口shutdown了,则执行undo shutdown操作。
03查看光模块光功率是否正常
执行display interface transceiver verbose命令查看光模块发送或接收光功率方面的信息,与光模块的标称光功率进行对比判断。
光模块的诊断信息中,可以查看当前发送和接收的光功率值,以及默认的最高和最低功率值。
<HUAWEI> display interface 10ge 1/0/1 transceiver verbose
10GE1/0/1 transceiver information:
-------------------------------------------------------------------
Common information:
Transceiver Type :10GBASE_SR
Connector Type :LC
Wavelength (nm) :850
Transfer Distance (m) :30(62.5um/125um OM1)
80(50um/125um OM2)
300(50um/125um OM3)
400(50um/125um OM4)
Digital Diagnostic Monitoring :YES
Vendor Name :HUAWEI
Vendor Part Number :02318169
Ordering Name :
-------------------------------------------------------------------
Manufacture information:
Manu. Serial Number :AQG269Y
Manufacturing Date :2013-10-20
Vendor Name :HUAWEI
-------------------------------------------------------------------
Alarm information:
-------------------------------------------------------------------
Diagnostic information:
Temperature (Celsius) :33.68
Voltage (V) :3.29
Bias Current (mA) :7.97
Bias High Threshold (mA) :13.20
Bias Low Threshold (mA) :4.00
Current RX Power (dBm) :-2.15
Default RX Power High Threshold (dBm) :1.00
Default RX Power Low Threshold (dBm) :-11.90
Current TX Power (dBm) :-2.07
Default TX Power High Threshold (dBm) :1.00
Default TX Power Low Threshold (dBm) :-9.30
------------------------------------------------------------------
1、如果接收功率低(Current RX Power < Default RX Power Low Threshold),说明本端接收到的信号过低;则可能出现端口不UP或者UP后报文收发有丢弃,此时请先排查传输距离是否过远,超出了该光模块的传输距离,再排查光模块、光纤是否有损坏。
2、如果接收功率高(Current RX Power > Default RX Power High Threshold),说明本端接收到的信号过高;可能原因是该光模块为长距光模块,而实际传输距离太短,导致信号未衰减,此时应在光模块上增加光衰,以对光模块进行保护。
3、如果发送功率低(Current TX Power < Default TX Power Low Threshold),说明该光模块发送信号不好或光模块本身故障;可能会导致对端接收功率低,而造成端口不UP或者UP后报文收发有丢弃,请与技术支持人员联系。
4、如果发送功率高(Current TX Power > Default TX Power High Threshold),说明该光模块发送信号太强;可能会导致对端接收功率高,而造成对端光模块因接收功率持续过高而烧坏,可能原因是本端光模块故障,建议更换光模块。因此,在端口插入光模块并对接成功后,要对发送或接收光功率方面的告警信息进行排查,避免因功率过低或者过高造成流量或者光模块不正常。
本文由本站注册用户:小路 发布上传,如若转载,请注明出处:https://www.luyou7.cn/wlyj/anzhuangfangfa/515.html,如本文侵犯您的权益,请邮件至3484479098@qq.com联系我们,我们将会在三个工作日内删除